What was found
FWD CARGO BAY 10 STRINGER 27 LEFT HAS 17 RIVETS WITH CORROSION. REMOVED 17 RIVETS SRM 51-40-02. CLEANED CORROSION AMM 51-21-31 FOUND 1EA AREA OUT OF LIMITS SRM 53-00-03 ALLOWABLE DAMAGE 1 DETAIL B. REMOVED DAMAGED STR 27L, FABRICATED REPAIR SPLICES & REPLACEMENT STR SRM 53-00-03 REPAIR 1 FIG 204. ALODINE & PRIMER AMM 51-21- 41 AMM 51-21-21, INSTALLED STR 27L BAY 9 & 10 SRM 53-00-03 PERFORMED LEAK CHECK. NO LEAKS NOTED AMM 05-51-91. SEE FORM 44.0008CM FOR ALL WORK PERFORMED.