What was found
TNN - DURING S-CHECK INSPECTION, CRACK WAS FOUND ON L2 GALLEY SERVICE DOOR EXIT SIGN COVER. THE DAMAGED EXIT SIGN ASSEMBLY WAS REMOVED AND REPLACED WITH (P/N BR727-105) ASSEMBLY PER B727 MM 33-50-11 AND OPERATIONAL CHECK FOUND SATISFACTORY. HANGAR NON ROUTINE REPAIR ITEM CARD NR 0725422 (SEQ NR 02078). (W)