What was found
KUL - HNRC: 844757 - FLOOR BEAM, STA 1070, RBL 50 INTERCOSTAL FOUND CORRODED. CORROSION REMOVED AND FOUND OUT OF LIMIT DEPTH 0.045 INCH AREA 2 INCHES BY 8 INCHES IAW SRM 53-10-1. REPLACED NEW INTERCOSTAL IAW SRM 53-10-2. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
KUL - HNRC: 844757 - FLOOR BEAM, STA 1070, RBL 50 INTERCOSTAL FOUND CORRODED. CORROSION REMOVED AND FOUND OUT OF LIMIT DEPTH 0.045 INCH AREA 2 INCHES BY 8 INCHES IAW SRM 53-10-1. REPLACED NEW INTERCOSTAL IAW SRM 53-10-2. (X)