What was found
REF N/R 3465, FLOOR INTERCOSTAL BLOWN OUT CORROSION AT BS 1020 APPROXIMATELY 30 INCHES LEFT OF CENTER LINE. FABRICATED NEW PART, 21 INCHES PIECE OF 130188-1-1 7075-T6511 T-EXTRUSION AND 12 INCH BY 21 INCH 7075-T6 .125 IAW SRM 51-10-1, ALODINE AND PRIMED AND PAINTED IAW SRM 51-10-2, INSTALLED IAW SRM 51-20-2. (M)