What was found
REF N/R 3658, SURFACE CORROSION ON FLOOR BEAM STATION 312 AT CLIP NUT HOLES FT OF COCKPIT DOOR (BOTH SURFACES). REMOVED CORROSION IAW SRM 51-10-6 AT 3 INCHES LT OF C/L AND AT 19 INCHES OF C/L MAX MATERIAL REMOVED .050, TREATED AND PRIMED IAW SRM 51-10-2. FABRICATED REPAIR IAW ENGINEERING REPORT NR 96-027. INSTALLED REPAIR IAW ENGINEERING REPORT 96-027. (M)