What was found
REF N/R 3626, CORROSION STATION 344 AT CLIP NUT HOLE FLOOR BEAM PANEL NR 2 FORWARD EDGE BOTH SURFACES. REMOVED CORROSION IAW SRM 51-10-6. INSPECTION FOUND OUT OF LIMITS, CUT OUT DAMAGED SECTION. FABRICATED REPAIR PARTS IAW SRM 53-10-8-8-2A USING BAC 1505-100617 EXT, 7075-T73 EXT .050 ANGLE, 7075-T73 EXT .090 ANGLE, 7075-T6, .090 FILLER, 7075-T6 .080 STRAP, 7075-T6 .050 STRAP IAW SRM 51-10-2. INSTALLED REPAIR ITEMS IAW SRM 53-10-2 AND 51-30-2. (M)