What was found
F/A REPORTED ODOR OF SMOKE NEAR ROW 17 LEFT SIDE. INSPECTED AND OPS CHECKED CABIN AND LAV LIGHTS, OVERHEAD BINS, GALLEY COMPARTMENT, AND TRASH CANS. ALSO OPS CHECKED GALLEY HEATER, PERFORMED BOTH ENGINE POWER RUNS AND CHECKED LT AND RT BLEED AND PACKS. NO SIGNS OF ODOR FOUND IN CABIN, LAV, OR COCKPIT AT THIS TIME. IAW AMM 33-20-00, 33-25-00, 21-23-64, 21-51-00, 36-10-00, AND 72-00-00.