Service difficulty report · Safety Valve · Cndair CL6002C10

Difficulty date
July 17, 2011
Submitted
July 18, 2011
Operation
Air carrier
Aircraft
N168GJ
Make and model
Cndair CL6002C10
Aircraft serial
10272
Aircraft time
7,128 hours, 4,859 cycles
Part
Safety Valve
Part number
GG670980051
Part serial
01146
Condition
Failed
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
B

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LEFT ENGINE BLEED DUCT WARNING MESSAGE OCCURRED AT 27,500 FT. CABIN ALTITUDE CAUTION MESSAGE AND MASKS DEPLOYED OCCURRED AT 29,500 FT. CABIN ALTITUDE CLIMBED AT 3,000 FT PER MIN, LOSS OF PRESSURIZATION, SMOKE IN CABIN AT 10,000 FT. OPS CHECKED NR 1 BLEED NO DEFECTS NOTED. R & R THE NR 2 SAFETY VALVE. PRESSURIZED ACFT NO DEFECTS NOTED IAW AMM 21-32-03. REF W/O 7036-1 THRU 7036-36 FOR OXEGEN GENERATOR REMOVAL AND REPLACEMENT.