What was found
PAX DOOR INDICATES OPEN WHEN DOOR IS CLOSED, RED DOOR INDICATION ON EICAS PANEL. ADJUSTED PX46 PROX SWITCH IAW AMM 52-70-04. PERFORMED OPERATIONS CHECK OF PAX DOOR IAW 52-70-00, OPERATIONS CHECKED GOOD AT THIS TIME.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAX DOOR INDICATES OPEN WHEN DOOR IS CLOSED, RED DOOR INDICATION ON EICAS PANEL. ADJUSTED PX46 PROX SWITCH IAW AMM 52-70-04. PERFORMED OPERATIONS CHECK OF PAX DOOR IAW 52-70-00, OPERATIONS CHECKED GOOD AT THIS TIME.