What was found
ANTI ICE DUCT MASTER WARNING IN FLIGHT. FOUND BLEED LEAK DETECTION LOOP MT173 AND MT174 ON LEFT WING A/I DUCT TO BE LOOSE. REINSTALLED BLEED LEAK DETECTION LOOP IAW CRJ 700 AMM 36-21-05. OPS CHECK GOOD. NO DEFECTS NOTED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ANTI ICE DUCT MASTER WARNING IN FLIGHT. FOUND BLEED LEAK DETECTION LOOP MT173 AND MT174 ON LEFT WING A/I DUCT TO BE LOOSE. REINSTALLED BLEED LEAK DETECTION LOOP IAW CRJ 700 AMM 36-21-05. OPS CHECK GOOD. NO DEFECTS NOTED.