What was found
CRACK AT STA 907, STR 4R STRINGER SPLICE. REMOVED AND REPLACED CRACKED STRINGER SPLICE AT STA 907 STR 4R IAW SRM 51-10-01 SECTION 7, FASTENERS INSTALLED IAW 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK AT STA 907, STR 4R STRINGER SPLICE. REMOVED AND REPLACED CRACKED STRINGER SPLICE AT STA 907 STR 4R IAW SRM 51-10-01 SECTION 7, FASTENERS INSTALLED IAW 51-30-2.