What was found
DAMAGE FOUND ON STRINGER SPLICE BS907, STR20L IN AFT PIT. DAMAGED STRINGER SPLICE AT BS907, STR20L IN AFT PIT REPLACED IAW SRM 51-10-01, PARA 7, REV 108. INSTALLED IAW SRM 51-30-02, REV 108. CORRODED SECTION OF STRINGER BETWEEN FS887-907 STR20L REPAIRED IAW SRM 53-10-03, FIG 1, REV 108 & INSTALLED IAW SRM 51-30-02, REV 108.