As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GOUGED FLOOR STRUCTURE WEB AT BS720. LBL25 AND BS710, LBL25. REPAIRED FLOOR STRUCTURE WEB AT BS720-710 LBL25 IAW AEI EO 1825 DTD 2 MAR 2015 & SB 737-57-1296, REV. PERFORMED REPAIR AS SHOWN IN FIG 19 OF SB WITH THE FOLLOWING EXCEPTIONS: A. DOUBLER "D" MADE FROM AL 7075-T6 CLAD/BARE, O.100" THICK. B. INSTALLED ALL REINFORCING ANGLES WITH SAME TYPE AND DIAMETER FASTENER.