What was found
AFT CARGO BAY BS 727, RBL 18, WL 200 CRACKED CLIP. DURING INSPECTION, A CRACKED CLIP WHICH SERVES TO SECURE THE UPPER END OF THE RBL 18 VERTICAL BEAM OF THE BS 727 BULKHEAD WAS NOTED. FABRICATED AND INSTALLED A REPLACEMENT CLIP IAW DWG 65-46547, REV DK AND SRM R108. THIS AREA IS NOT PART OF THE BS 727 BULKHEAD, LONGITUDUNAL FLOORBEAM AD AREA, REF KFC MCO 3218, WO 1365527.