What was found
UPPER FUSELAGE FLOOR CORRODED SHEAR WEB BS 616 TO BS 639, RBL 65, STR 17R. DURING INSPECTION, OUT OF LIMITS, CORROSION WAS NOTED ON THE CREASEBEAM WEB BETWEEN BS 616 AND BS 639, RT. FABRICATED AND INSTALLED REPLACEMENT WEB.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPPER FUSELAGE FLOOR CORRODED SHEAR WEB BS 616 TO BS 639, RBL 65, STR 17R. DURING INSPECTION, OUT OF LIMITS, CORROSION WAS NOTED ON THE CREASEBEAM WEB BETWEEN BS 616 AND BS 639, RT. FABRICATED AND INSTALLED REPLACEMENT WEB.