What was found
CORROSION ON FLOOR SUPPORT BS 986 - 1016 RBL 40 JUST AFT OF R2 DOOR. CORROSION FOUND TO BE BEYOND ALLOWABLE LIMITS. REPLACED IAW SRM REV.110 53-10-2, ITEM 62.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT BS 986 - 1016 RBL 40 JUST AFT OF R2 DOOR. CORROSION FOUND TO BE BEYOND ALLOWABLE LIMITS. REPLACED IAW SRM REV.110 53-10-2, ITEM 62.