What was found
PRV EICAS. REMOVED AND REPLACED RH ENG PRV CONTROLLER IAW B767 AMM 36-11-19 OPS/LEAK CHECK GOOD PER AMM 71-00-00, ENGINE RUN AND ETOPS VERIFICATION COMPLIED WITH. DTO POOL PART, NO TIME INFO AVAILABLE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PRV EICAS. REMOVED AND REPLACED RH ENG PRV CONTROLLER IAW B767 AMM 36-11-19 OPS/LEAK CHECK GOOD PER AMM 71-00-00, ENGINE RUN AND ETOPS VERIFICATION COMPLIED WITH. DTO POOL PART, NO TIME INFO AVAILABLE.