What was found
CRACK INDICATION FOUND AT STR 10R AT BS 500L -1 7/8" AND BS 500L + 1 6/8" TOTAL CRACK LENGTH 3 5/8". REPAIRED CRACK ON STR 10R PER SRM 53-00-01 REPAIR 30 FIG 201, ASSOCIATED WORKSHEETS AND IAW EO 5323-077 REV 1R
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK INDICATION FOUND AT STR 10R AT BS 500L -1 7/8" AND BS 500L + 1 6/8" TOTAL CRACK LENGTH 3 5/8". REPAIRED CRACK ON STR 10R PER SRM 53-00-01 REPAIR 30 FIG 201, ASSOCIATED WORKSHEETS AND IAW EO 5323-077 REV 1R