What was found
DURING APU OPERATION DUCT PRESSURE GO TO 10 PSI AND FLUCTUATED ON GROUND. REPLACED INLET GUIDE ACTUATOR IAW AMM 49-52-02/401. APU STARTING AND OPERATION NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING APU OPERATION DUCT PRESSURE GO TO 10 PSI AND FLUCTUATED ON GROUND. REPLACED INLET GUIDE ACTUATOR IAW AMM 49-52-02/401. APU STARTING AND OPERATION NORMAL.