What was found
LH FIXED TRAILING EDGE UPPER INBD PANEL ANGLE BRACKET CRACKED. STOP DRILLED END OF CRACK. FABRICATED CBER 15-5 050 FOR HEAT TREAT - ROCKWELL TEST @33. PRIMED AND INSTALLED REF B737-400 SRM 51-51-90 AND EO 737-00003
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LH FIXED TRAILING EDGE UPPER INBD PANEL ANGLE BRACKET CRACKED. STOP DRILLED END OF CRACK. FABRICATED CBER 15-5 050 FOR HEAT TREAT - ROCKWELL TEST @33. PRIMED AND INSTALLED REF B737-400 SRM 51-51-90 AND EO 737-00003