Service difficulty report · Actuator · Boeing 7673BG

Difficulty date
December 30, 2025
Submitted
January 13, 2026
Operation
Air carrier
Aircraft
N563NC
Make and model
Boeing 7673BG
Aircraft serial
30563
Aircraft time
86,717 hours, 22,239 cycles
Part
Actuator
Condition
Failed
Location
Apu Fuel Shutoff
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

APU FUEL SHUT OFF VALVE FAILED AN OPS CHECK. APU FIRE SWITCH CHECK, DOES NOT CLOSE OR OPEN ELECTRICALLY. R & R THE APU SHUT OFF VALVE ACTUATOR IAW AMM 28-25-00-004-032, & AMM 28-25-02-404-008 STEPS 3.G. (3) - 3.G (8). PERFORMED APU FUEL FEED SYS TEST. TESTED GOOD IAW AMM 28-25-00-715-264.