What was found
DURING ANNUAL INSPECTION, DAMAGE WAS DISCOVERED ON LT LOWER WING SKIN AT FUEL SUMP ACCESS PANEL LOCATED AT WS 102.25. ONE MINOR CRACK IN FWD INBD CORNER AND MEASURES .200" IN LENGTH AND IS .050" FROM THE CLOSEST FASTENER. ANOTHER MINOR CRACK IS IN THE AFT OTBD CORNER AND MEASURES .125" IN LENGTH AND IS .310" FROM THE CLOSEST FASTENER. THE AFFECTED AREAS FALL WITHIN THE AREA COVERED BY THE ORIGINAL AMOC FOR AD2002-19-13. ON SITE DER DISPOSITION WITH ACO ENGINEERING INVOLVEMENT IS IN-PROGRESS.