What was found
FOUND LEFT TRANSITION PANEL CORRODED AT STATION 1530 TO 1610. REMOVED CORROSION PER SRM 51-10-02. REINSPECT AND EVALUATED FOR CORROSION, ALODINED AND PRIMED TRANSITION POWER PER 51-20-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND LEFT TRANSITION PANEL CORRODED AT STATION 1530 TO 1610. REMOVED CORROSION PER SRM 51-10-02. REINSPECT AND EVALUATED FOR CORROSION, ALODINED AND PRIMED TRANSITION POWER PER 51-20-01.