What was found
LEFT COMMAND EPR SECTOR CONSTANTLY IN VIEW, ACTUAL EPR NEVER CAUGHT UP TO COMMAND THRUST LEVEL. N1, N2, N3 EICAS INDICATIONS AND STANDBY N1 INDICATIONS OPS NORMAL. REPLACED THE THRUST MANAGEMENT COMPUTER PERFORMED ENGINE RUN, OPS CHECKED NORMAL.