What was found
ACFT ABORTED TAKEOFF DUE TO RIGHT ENGINE BLEED OFF LIGHT ILLUMINATED. TROUBLESHOT SYSTEM FOUND FAULTY PRSOV. REPLACED VALVE AS PER MM 36-11-09 OPS. CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ACFT ABORTED TAKEOFF DUE TO RIGHT ENGINE BLEED OFF LIGHT ILLUMINATED. TROUBLESHOT SYSTEM FOUND FAULTY PRSOV. REPLACED VALVE AS PER MM 36-11-09 OPS. CHECKED GOOD.