What was found
NR 2 PYLON IS CRACKED ON INBD MOUNTING FLANGE FOR THE AFT STRUT FAIRING PANEL 447DB. CRACK MEASURES 6" LONG. R & R NEWLY FABRICATED NR 2 PYLON MOUNTING FLANGE IAW SRM 51-40-02, DWG 313T3380 USING 2024T3, .063.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 PYLON IS CRACKED ON INBD MOUNTING FLANGE FOR THE AFT STRUT FAIRING PANEL 447DB. CRACK MEASURES 6" LONG. R & R NEWLY FABRICATED NR 2 PYLON MOUNTING FLANGE IAW SRM 51-40-02, DWG 313T3380 USING 2024T3, .063.