What was found
TAKEOFF ROLL POWER PUSHED UP AUTOCOARSEN LIGHT CAME ON. PERFORMED TROUBLESHOOTING IAW SAAB AMM 61-22-00, FAULT ISOLATION. CHECKED WIRING TO P3 SWITCHES AND TEST SWITCHES. NO FAULTS FOUND. REMOVED AND REPLACED AUTO COARSEN COMPUTER IAW SAAB AMM 61-22-00, OPS CHECK GOOD, P/N 8542M2, S/N ON: 206, S/N OFF: 387.