What was found
GUST LOCK LIGHT AND RUDDER LIMITER ILLUMINATED DURING FLT CNTRL SYSTEM TEST. COULD NOT DUPLICATE GUST LOCK LIGHT. GUST LOCK OPERATES CORRECTLY IAW MM 27-72-00. VERIFIED RUDDER LIMITER OPERATION. RUDDER LIMITED PASSED FUNCTIONAL TEST IAW MM 27-72-00-00. MEL CLEARED.