What was found
DURING "M" CHECK, FOUND SHORT EDGE MARGIN ON UPPER DECK FLOORBEAM REINFORCEMENT STRAPS AT BS 380 RT AND LT. ALSO, FOUND CRACK IN FLOORBEAM CHORD FASTENER HOLE AT BS 380 RBL 74. REPAIRED PER EA 67-208994.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING "M" CHECK, FOUND SHORT EDGE MARGIN ON UPPER DECK FLOORBEAM REINFORCEMENT STRAPS AT BS 380 RT AND LT. ALSO, FOUND CRACK IN FLOORBEAM CHORD FASTENER HOLE AT BS 380 RBL 74. REPAIRED PER EA 67-208994.