What was found
HEAVY CORROSION ON INNER LOWER DOOR JAMB FRAME FROM FWD TO AFT CORNER FWD CARGO DOOR CUTOUT. BLENDED OUT CORROSION LESS THAN 20 PERCENT. DOES NOT REQUIRE FURTHER RE WORK, IAW SRM 53-05 PG 173 SEC B-13. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HEAVY CORROSION ON INNER LOWER DOOR JAMB FRAME FROM FWD TO AFT CORNER FWD CARGO DOOR CUTOUT. BLENDED OUT CORROSION LESS THAN 20 PERCENT. DOES NOT REQUIRE FURTHER RE WORK, IAW SRM 53-05 PG 173 SEC B-13. (M)