SDR ORJA98193

Service difficulty report · Overheat Loop · Doug DC982

Difficulty date
August 13, 1998
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N822RA
Make and model
Doug DC982
Aircraft serial
49932
Part
Overheat Loop
Condition
Malfunctioned
Location
Tail Compt
Stage of operation
NR
Nature of condition
N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FROM RENO, AIR TURNBACK TO RENO, TAIL COMPT TEMP HIGH LIGHT CAME ON AFTER TAKEOFF. STAYED ON FOR 3 MINUTES. WENT OUT ON FIRST POWER REDUCTION. RAN ENGINES NR 1 AND NR 2 AND APU AT TAKEOFF POWER 3 TIMES. COULD NOT DUPLICATE TAIL TEMP HIGH LIGHT AT THIS TIME. SYSTEM OPS CHECKS NORMAL, AND NO LEAKS NOTED. (M)