What was found
LEVEL 2 CORROSION ON SEVERAL HI-LOCK NUTS ON STRINGER 29R BETWEEN STATION 1117 AND 1130. REMOVED CORRODED HI-LOCK NUTS ON STRINGER 29R, BETWEEN STATION 1117 AND 1130. INSTALLED SERVICEABLE NUTS AND WASHERS IAW DC9 SRM 51-30-5. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION ON SEVERAL HI-LOCK NUTS ON STRINGER 29R BETWEEN STATION 1117 AND 1130. REMOVED CORRODED HI-LOCK NUTS ON STRINGER 29R, BETWEEN STATION 1117 AND 1130. INSTALLED SERVICEABLE NUTS AND WASHERS IAW DC9 SRM 51-30-5. (M)