What was found
LEVEL 3 CORROSION ON AFT PIT SHEAR TIE AT STATION 1155 BETWEEN STRINGER 29R AND 29L. FABRICATED NEW SHEAR TIE IAW SRM 51-10-1 AND REINSTALLED ALL PARTS IAW DC-9 AND 51-30-2, OPS CHECK GOOD IAW MD-80 MM 21-00-00. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 3 CORROSION ON AFT PIT SHEAR TIE AT STATION 1155 BETWEEN STRINGER 29R AND 29L. FABRICATED NEW SHEAR TIE IAW SRM 51-10-1 AND REINSTALLED ALL PARTS IAW DC-9 AND 51-30-2, OPS CHECK GOOD IAW MD-80 MM 21-00-00. (M)