What was found
LEVEL 3 CORROSION FLOOR SUPPORT ANGLE FORWARD OF L-1 DOOR AREA FS FORWARD OF STATION 160 HAS CORROSION AT DOME NUT AREA AND INTERIOR SURFACE. REMOVED, FABRICATED, TREATED, PRIMED AND REINSTALLED NEW FLOOR SUPPORT ANGLE IAW DC-9 SRM 51-10-2, 21-10-3, 51-10-4 AND 51-30-2. (M)