What was found
LEVEL 2 CORROSION ON FLOR SUPPORT CUSP ANGLE RBL 54 STATION 168 LOWER FORWARD CORNER OF R1 DOOR CUTOUT (OTBOARD SIDE). CUT OUT CORRODED SECTION FABRICATED REPAIR DOUBLER, SEALED AND INSTALLED IAW MD83 SRMS 51-10-3, 53-01. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LEVEL 2 CORROSION ON FLOR SUPPORT CUSP ANGLE RBL 54 STATION 168 LOWER FORWARD CORNER OF R1 DOOR CUTOUT (OTBOARD SIDE). CUT OUT CORRODED SECTION FABRICATED REPAIR DOUBLER, SEALED AND INSTALLED IAW MD83 SRMS 51-10-3, 53-01. (M)