What was found
AT PHOENIX LEVEL 2 CORROSION, LOWER CHORD ANGLE, STATION 1002, HAS CORROSION BEYOND LIMITS. REMOVED LOWER CHORD ANGLE 24542 1002. REMOVED TRACK SUPPORT ANGLES FOM. INSTALLED SPLICE, P/N 3936445-1 PO NR X9S454606. TRACK SUPPORT ANGLES TO BE INSTALLED ON WO NR 1499-17-K020. SRM FOR SPLICE INSTALLATION 51-30-0. VERIFIED WO NR 1499-17-K020, CORROSION REMOVED. (M)