What was found
SJO - DURING Q-CHECK, FOUND FRAME DENTED AT BS 500A, BETWEEN STRINGER 24L AND 22L. REPAIRED FRAME AT BS 500A BETWEEN STRINGER 26L AND 21L IAW SRM 51-40-3 FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SJO - DURING Q-CHECK, FOUND FRAME DENTED AT BS 500A, BETWEEN STRINGER 24L AND 22L. REPAIRED FRAME AT BS 500A BETWEEN STRINGER 26L AND 21L IAW SRM 51-40-3 FIG 1. (M)