What was found
SJO - DURING Q-CHECK, FOUND CORROSION ON FLOORBEAM AT BS 259.5, WL 208 AND BETWEEN RBL 5 AND RBL 10. REPAIRED FLOORBEAM UPPER CHORD, BETWEEN RBL 10 AND LBL 29 AIW SRM 51-40-4, FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SJO - DURING Q-CHECK, FOUND CORROSION ON FLOORBEAM AT BS 259.5, WL 208 AND BETWEEN RBL 5 AND RBL 10. REPAIRED FLOORBEAM UPPER CHORD, BETWEEN RBL 10 AND LBL 29 AIW SRM 51-40-4, FIG 1. (M)