What was found
YXD - DURING C-CHECK, FOUND TIE CLIP ANGLE AT BS 360, STRINGER 14-15L WITH CRACK, .5 INCHES LONG. FABRICATED AND REPLACED TIE CLIP ANGLE AT BS 360, STRINGER 14-15L PER SRM 51-10-1, 51-30-2 WORK ACCOMPLISHED ON NON-ROUTINE NR 0344. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
YXD - DURING C-CHECK, FOUND TIE CLIP ANGLE AT BS 360, STRINGER 14-15L WITH CRACK, .5 INCHES LONG. FABRICATED AND REPLACED TIE CLIP ANGLE AT BS 360, STRINGER 14-15L PER SRM 51-10-1, 51-30-2 WORK ACCOMPLISHED ON NON-ROUTINE NR 0344. (M)