What was found
SJO - DURING C-CHECK, FRAME DENTED AND CORRODED AT BS 500 BETWEEN STRINGERS 24R AND 26R. REPAIRED FRAME AT BS 500 BETWEEN STRINGERS 23R AND 25R IAW SRM 51-40-3, FIG 1. SEE COOPESA W/O N10316-1-47 VAM 100 NR 210 AND 912SDA120. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SJO - DURING C-CHECK, FRAME DENTED AND CORRODED AT BS 500 BETWEEN STRINGERS 24R AND 26R. REPAIRED FRAME AT BS 500 BETWEEN STRINGERS 23R AND 25R IAW SRM 51-40-3, FIG 1. SEE COOPESA W/O N10316-1-47 VAM 100 NR 210 AND 912SDA120. (X)