What was found
SJO - DURING C-CHECK, FOUND CABIN STUB BEAM WEB AT BS 616 FROM RBL 45 TO RBL 56 BETWEEN WL 208 AND WL 200 HAS CRACK. L = 0.373 INCH. W = 0.0005 INCH. REPAIRED STUB BEAM AT BS 616 FROM RBL 45 TO RBL 56 BEWEEN WL 208 AND WL 200 IAW BOEING SB 737-53-1061 REV 4 DATED 7-16-92 SECTION III, PART III, PARA B. SEE COOPESA WO NR N10316-1-244 AND VAM 100-0784. (X)