What was found
SJO - DURIG C-CHECK, FOUND THE LEFT MAIN LANDING GEAR CENTER DOOR TRAILING EDGE WITH CRACK 2 INCHES LONG BY .002 INCHES WIDE. REPAIRED THE LEFT MAIN LANDING GEAR CENTER DOOR TRAILING EDGE IAW SRM 51-40-3 FIG 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SJO - DURIG C-CHECK, FOUND THE LEFT MAIN LANDING GEAR CENTER DOOR TRAILING EDGE WITH CRACK 2 INCHES LONG BY .002 INCHES WIDE. REPAIRED THE LEFT MAIN LANDING GEAR CENTER DOOR TRAILING EDGE IAW SRM 51-40-3 FIG 1. (M)