What was found
SJO - DURING Q-CHECK, FOUND EXTERNAL FUSELAGE SKIN WITH DENT AT BS 500A PLUS 12, BETWEEN STRINGER 1 AND STRINGER 2L. REPAIRED FUSELAGE SKIN SECTION FROM BS 500A PLUS 7 INCHES TO 500B, BETWEEN STRINGER 2 LEFT AND STRINGER 2 RIGHT DUE TO DENT IAW SRM 53-30-3 FIG 07. (M)