What was found
During "C" Check Inspection.-R-H NLG Door, P/N 65-50520-504, S/N BNW330 Found With Delamination.-Repaired R-H NLG Door Due to Delamination From BS294.5 to BS262.5, IAW COOPESA EO No.COO-CMP-3-52-614-01, Dated Nov 07, 2001 & Documented on FAA 8110-3 Form Approved by DERT-7101676-SW.Note: See COOPESA Work Order No. O10863 6-46, VAM100 No.238 & 122SDA102.