As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PAE - FOUND DURING VISUAL INSPECTION, 81 INCHES BY 2 INCHES OF CORROSION ON FLOORBEAM AT BS 294 LBL 32 TO RBL 49 WL 608. AREA PREVIOUSLY REWORKED. REMOVED DAMAGED SECTION OF CHORD, FABRICATED AND INSTALLED NEW CHORD PER SRM 53-10-9 FIG 5. (M)