What was found
PAE - FOUND C-CHECK MAINTENANCE VISIT, NON-ROUTINE WRITE-UP, WHILE WORKING (962753A062-R) DISCOVERED CRACKED FLOOR SUPPORT AT BS 663.75, RBL 60, WL 208. REMOVED CRACKED FLOOR SUPPORT FROM BS 52-672, RBL 60, WL 208. INSTALLED NEW FLOOR SUPPORT IAW SRM 51-40 AND SRM 51-30-5. INSTALLED FASTENERS IAW SRM 51-30-2. ALODINED AND PRIMED IAW SRM 51-10-2. (M)