What was found
PAE - FOUND C-CHECK MAINTENANCE VISIT, WHILE WORKING N/R 0217 DISCOVERED STRINGER SPLICE, TO BE CORRODED AND CRACKED, BS 912, STRINGER 24 LEFT. REMOVED CORRODED STRINGER SPLICE, BS 904 TO 912 STRINGER 24 LEFT. INSTALLED NEW STRINGER SPLICE BS 904 TO 912 STRINGER 24 LEFT, PER SRM 51-10-1 AND 51-30-2. THIS HAS BEEN CLASSIFIED AS LEVEL 2 CORROSION PER BAC CPCP. (M)