What was found
SJO - FUSELAGE FRAME CRACKED, IN FORWARD CARGO COMPARTMENT AT BS 460, BETWEEN STRINGER 28L AND 27R, CRACK SIZE 11 INCH BY 4 INCH. REPAIRED FUSELAGE FRAME CRACK, PER SRM 53-10-4 FIG 10. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SJO - FUSELAGE FRAME CRACKED, IN FORWARD CARGO COMPARTMENT AT BS 460, BETWEEN STRINGER 28L AND 27R, CRACK SIZE 11 INCH BY 4 INCH. REPAIRED FUSELAGE FRAME CRACK, PER SRM 53-10-4 FIG 10. (M)