What was found
SJO - DURING C-CHECK ROUTIN EINSPECTION AS PER WORK CARD J2C-51-2525, A CRACK WAS FOUND ON STRINGER NR 23 RT, BETWEEN BS 493 AND BS 514. THE CRACK WAS .25 INCH LONG. THE CRACK WAS REPAIRED AS PER SRM 53-10-03. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SJO - DURING C-CHECK ROUTIN EINSPECTION AS PER WORK CARD J2C-51-2525, A CRACK WAS FOUND ON STRINGER NR 23 RT, BETWEEN BS 493 AND BS 514. THE CRACK WAS .25 INCH LONG. THE CRACK WAS REPAIRED AS PER SRM 53-10-03. (M)