What was found
DURING C-CHECK WHILE PERFORMING ROUTINE INSPECTION PER WORK CARD J2C-512525, CORROSION WAS FOUND AT STR 26 LEFT BETWEEN BS 500 B + 16 INCHES AND BS 528. THE CORROSION WAS OUT OF LIMITS (10 PERCENT REMOVED) PER THE SRM. THE STRINGER WAS REPAIRED IAW SRM 53-10-03, FIG 1, SHT 6. REF: COOPESA W.O. L1-0630-1-32, VAM100-195, 208SKA005. (X)